BMI Redland Half Round Ridge Vent Rustic Red
£167.76 £139.80
In stock
SKU
725378
Est. delivery: 3-5 Working Days
Est. delivery: 3-5 Working Days
Key Highlights
- Over 35 Years Of Trading
- Expert Assistance
- Huge Stock
- Best Price Promise
- 9 Store Locations
BMI Redland Half Round Ridge Vent Rustic Red
The Ridge Ventilation Terminal is a neat method of providing ventilation to a soil ventilation pipe or mechanical ventilation system at ridge level. It will also provide roof space ventilation at high level.
Description
- Ventilates to comply with BS 5250:2011, therefore reducing the risk of harmful condensation in the roof
- Tried and tested and complies with BS 5534:2014 requirements for mechanical fixing
- Complies with BS EN 12056-2:2000 Gravity Drainage Systems Inside Buildings
General Information
Compatibility
- Available in concrete Half Round and Universal Angle Ridge Tiles
- Not suitable for use with Uni-Vent Rapid Ridge/Hip, Continuous Ridge or on hip details
- Cannot be used as a gas flue
Performance
- Minimum and maximum pitch will depend on the tile profile and whether ridge tiles are dry fixed or mortar bedded
- The effective ventilation area for each terminal is 8,400mm2
- To achieve roof space ventilation of 5,000mm2/m run, they should be spaced at 1.68m centres
- The pressure/air flow resistance characteristics of the terminal are as follows:
- At 15 litres/sec – 6.5 Pa
- At 30 litres/sec – 26 Pa
- At 60 litres/sec – 104 Pa
Colours
Half Round Ridge Ventilation Terminals are available in the following colours:
- Brown
- Antique Red
- Terracotta
- Tudor Brown
- Slate Grey
- Rustic Red
Universal Angle Ridge Ventilation Terminals are available in the following colours:
- Slate Grey
- Terracotta
- Tudor Brown
Fixing
Details
- Terminals are suitable for timber trussed rafter and timber sarking constructions. Where traditional timber rafter construction is used, trimmers will be required for each terminal position to allow a 300mm section of the ridge board to be removed.
- Where Terminals are used in conjunction with DryVent Ridge and are required in close proximity, at least one rafter spacing will be required between each terminal to allow adequate fixing of the ridge batten after a section has been removed.
- The position of the Terminal should not be within 600 mm of a gas flue such that foul gases can vent back into the building.
- The Terminal is not suitable for hot flue gases, or for use on hips.
- For soil pipe termination do not install within 3 m horizontally and 900 mm vertically of an opening, e.g. roof windows and roof space ventilation.
RIDGE VENT TERMINAL & COMPONENT DIMENSIONS
Vent Terminal Dimensions
Adaptor & Pipe Dimensions
Ridge Tile | U | V | W | X |
---|---|---|---|---|
Half Round | 98 | 256 | 450 | 52 |
Universal Angle | 106 | 256 | 450 | 34 |
Clay Half Round | 128 | 256 | 450 | 52 |
Heathland | 98 | 256 | 450 | 52 |
Product Features
- Neat method of providing ventilation
- Cannot be used as a gas flue