Complies fully with relevant Building Regulations and British Standards
Performance
The Vent Tile is positioned in line with the tile below and a hole is cut in the felt to accommodate downpipe. To ensure the integrity of the underlay the use of the Klober underlay seal is strongly recommended. The rigid base is then nailed to the batten. The skirt is dressed to the tile profile. A tile is laid to the right of the base, with the PVC on back upstand positioned above and below sidelock. The cap is clipped securely to the base and tiling is continued as normal.
NB. For plain tiles ensure that the minimum gauge is 100mm. Full instructions provided with each product.
Installation
Provides 30,000mm2 vent area (15,000mm2 effective area); 5mm, 10mm and 25mm continuous opening equivalent at 3m, 1.5m and 0.6m intervals respectively; and pressure air flow resistance at:-
15 litres/sec 30 litres/sec 60 litres/sec
Pascals 3.5 14 56